Product introduction
The Battery Charge and Discharge Tester is a specialized testing device used for detecting, evaluating, and maintaining battery performance. By performing controlled charging, constant-current discharging, capacity testing, cycle testing, and data logging on batteries, it determines the actual capacity, state of health (SOH), remaining service life, and whether there are any performance degradation issues.
![]() | ![]() |
Product functions
1. Battery capacity testing (core function)
By setting the discharge current and allowing the battery to discharge under specified conditions, the following parameters are recorded simultaneously:
Discharge voltage variation
Corriente de descarga
Discharge time
Output capacity (Ah)
Output energy (Wh)
2. Battery charge-discharge cycle testing
The equipment can automatically execute:
Charge → Discharge → Recharge → Redischarge
Cycle testing for battery life evaluation.
Primarily used for:
New battery life verification
Battery consistency analysis
Aging testing
R&D testing
3. Battery maintenance and activation
For long-term standby batteries (e.g., UPS, power system batteries), prolonged floating charging may lead to:
Capacity degradation
Imbalance among individual cells
Plate sulfation
Parámetros técnicos
Parámetros técnicos
| Modo de trabajo | Se puede usar solo, se puede usar simultáneamente, puede ser control remoto y monitoreo de estado. | |||
| Applicable battery | 48V | 110V | 220V | 380V |
| Tensión de carga | 40~60V | 95~150V | 190~300V | 350~450V |
| Corriente de carga | 10~150A | 1~80A | 1~40A | 1~20A |
| voltaje de descarga | 10~60V | 80~135V | 80~270V | 300~460V |
| Corriente de descarga | 0~150A | 0~200A | 0~100A | 0~60A |
| Precisión de la corriente | 1% | |||
| Precisión de voltaje | 0.5% | |||
| Precisión del voltaje del monómero | 0.2% | |||
| voltaje de monómero | 0.500V~16.00V(resolution 1mv) | |||
| Tiempo de descarga de carga | 0 ~ 99 horas y 59 minutos | |||
| Fuente de alimentación | CA: 220 V/380 V | |||
| Modo de enfriamiento | refrigeración por aire forzado | |||
| Manera de manejo | industrial universal wheel | |||
Ambiente de trabajo
| Disipación de calor | refrigeración por aire forzado |
| Temperatura | working range: -5 ~ 50℃ storage temperature: -40 ~ 70℃ |
| Humedad | relative to humidity0 ~ 90% (40±2℃) |
| Altitud | altitud nominal: 4000 m |
| Ruido | ﹤60dB |
Fuente de alimentación de trabajo
| Voltaje | Sistema trifásico monofásico: 220V AC (- 20% ~ +30%), frecuencia :45 ~ 65Hz |
| Prueba de tensión soportada | entrada - carcasa: 2200V DC 1min |
| entrada-salida: 2200V CC 1min | |
| salida - carcasa: 700V DC 1min | |
| Seguridad | cumplir con EN610950 |
Alambrado
| entrada de CA | Gb socket, suitable for 1 ~ 1.5mm2cable |
| Salida CC | instrument 25 mm2Cable quick connect plug (red positive black negative) |
Apodo: Probador de descarga de carga de batería; Probador de carga de batería
Características
1. Integración cinco en uno de carga, descarga, detección de una sola unidad, monitoreo y activación en línea, con funciones completas y funciones multipropósito;
2. Función de monitoreo inalámbrico de voltaje de una sola celda, cada módulo de monitoreo inalámbrico puede monitorear 12 monómeros al mismo tiempo;
3. Con software de análisis de antecedentes chino, con función de descarga de control remoto;
4. The host has a USB interface and a 2G large-capacity internal data storage space;
5. Usar CPU duales para trabajar juntas para garantizar la seguridad, confiabilidad y precisión de la prueba;
6. Se pueden realizar pausas y modificaciones de parámetros durante el proceso de descarga sin finalizar la prueba de descarga.
Application Scenarios
Substations
Testing the capacity and state of health (SOH) of DC screen battery banks
Used for periodic battery maintenance and acceptance testing
Power plants
Testing the performance of backup power batteries at power stations
Ensuring reliable power supply during emergency situations
Telecom base stations / communication rooms
Testing the capacity of communication backup batteries
Ensuring operation of communication equipment during power outages
Data centers / UPS rooms
Testing the discharge capability of UPS battery banks
Preventing backup power failure
New energy storage power stations
Testing the performance of energy storage battery clusters
Used for lithium battery capacity and cycle life testing
Battery manufacturers
Used for factory testing of cells, battery modules, and PACKs
Performing charge-discharge cycle testing
New energy vehicle industry
Testing the performance and degradation of power batteries
Used for battery maintenance and R&D analysis
Research institutions / laboratories
Used for new battery R&D and performance research
FAQs
q: What isa Battery Charge and Discharge Tester?
A: A Battery Charge and Discharge Tester is a testing device used to evaluate the charging and discharging performance and capacity status of batteries. It can assess battery health, remaining capacity, and service life.
Q: What types of batteries is this device suitable for?
A: It is suitable for:
Lead-acid batteries
Valve-regulated lead-acid batteries (VRLA)
UPS batteries
Lithium iron phosphate (LiFePO₄) batteries
Ternary lithium batteries
Energy storage battery packs, and more.
Q: Why is battery charge-discharge testing necessary?
A: Through testing, it is possible to:
Determine whether the actual battery capacity meets the specified standards
Identify batteries with capacity degradation
Prevent backup power failures in advance
Extend battery service life
Improve the reliability of the power supply system
Q: What is the difference between a battery charge-discharge tester and an ordinary battery charger?
A: An ordinary battery charger can only charge the battery, while a battery charge-discharge tester can:
Perform active discharge testing
Measure capacity
Record data
Analyze battery performance