qiao@hvtest.cc15871365102
  • YDQW Series Inflatable No Partial Discharge Test Transformer

    SF6 gas with high insulation strength as insulation medium. Small local discharge capacity, rated voltage local discharge capacity ≤ 5PC. High level craftsmanship, beautiful appearance, and easy handling

    Product Details of YDQW Series Inflatable No Partial Discharge Test Transformer

    Product Introduction:

    Used for manufacturers of electrical appliances, cables, motors, transformers, mutual inductors, insulation materials, and related high-voltage components, as well as high-voltage testing laboratories in power, scientific research, and universities, to conduct partial discharge and power frequency withstand voltage tests on their products.


    Technical parameters:

    Parámetros

    Value

    Capacidad nominal

    50-1200kVA

    Voltaje de entrada

    380V

    Tensión de salida

    50-1200kV

    Tiempo de ejecución

    ≤5 minutos

    Precisión de la medición

    ≤1.5%

    Partial discharge capacity

    ≤5Pc

    Protection function

    Overcurrent and voltage protection alarm automatically return to zero


    Característica:

    1. Filled with SF6 gas, which features high insulation strength, as the insulating medium.

    2. Compact and lightweight design with high-quality craftsmanship, attractive appearance, and easy handling.

    3. Benefiting from the arc-extinguishing properties and specialized structural design involving SF6 gas, the unit exhibits low partial discharge levels, measuring ≤5 PC at rated voltage.

    4. The testing process is simple, intuitive, and user-friendly.

    5. Effectively eliminates clutter interference from the power supply.

    6. Integrates automatic control technology, offering a high degree of automation and strong anti-interference capability.

    7. Equipped with a fast-acting electronic protection device, ensuring high reliability.


    Working principle:

    The control panel (box) with overcurrent automatic tripping and zero position interlocking device to prevent sudden pressurization of the power input is regulated by an autotransformer to input voltage into a non partial discharge filter isolation filter transformer, and then output from the non partial discharge filter isolation filter transformer

    To test the primary winding of the transformer, according to the principle of electromagnetic induction, the secondary (high voltage) winding can obtain an equal multiple of voltage amplitude - power frequency high voltage - based on the ratio of its turns to the primary winding.








    También podría gustarte

    • ¡Tiene alguna pregunta!

      NO DUDE EN CONTACTARNOS EN CUALQUIER MOMENTO
      Contáctenos
    • Visítanos

      Edificio 6, Parque Industrial Óptico-Mecánico Optics Valley, 84 Gaoxin 5 Road,
      Zona de desarrollo de nuevas tecnologías de East Lake, ciudad de Wuhan, provincia de Hubei, China

    • Envíanos un correo electrónico

      qiao@hvtest.cc

    • Llámanos

      +86-15871365102