qiao@hvtest.cc15871365102
  • Detector ultrasónico de descarga parcial portátil UHV-8003

    El detector ultrasónico portátil de descarga parcial UHV-8003 se utiliza principalmente para recibir la señal ultrasónica generada por la descarga parcial para juzgar la existencia y la ubicación donde se produce la descarga parcial del transformador, GIS, motor, cable y aislante y cable aéreo, etc. Está compuesto principalmente por: Detector ultrasónico portátil de descarga parcial: host principal, sensor ultrasónico de contacto, alta frecuencia

    Detalles del producto del detector ultrasónico de descarga parcial portátil UHV-8003



    UHV-8003 Partial Discharge Detector

    HTY_7649

    Product Introduction

    Partial discharge detector manufactures can be widely used for partial discharge detection in power systems, including insulation state detection of high-voltage and other equipment. The discharge degree of electrical equipment can be measured by the following indicators.

    This product can be widely used in partial discharge detection of power system, including high voltage switchgear, ring network cabinet, voltage / current transformer, transformer (including dry type transformer), GIS, overhead line, cable and other equipment insulation state detection, through the following indicators to measure the discharge degree of electrical equipment

    Partial discharge intensity detection: by measuring the discharge signal in one power frequency cycle, the partial discharge intensity is characterized according to the maximum value (dB) in the discharge pulse sequence

    Partial discharge frequency detection: by measuring the discharge signal in one power frequency cycle, the discharge pulse is extracted and the partial discharge frequency is characterized according to the number of discharge pulses.


    HTY_7580

    Product application

    Power generation and distribution enterprises

    Rail system

    Petrochemical power supply system

    Aerospace testing field

    Automated inspection field


    Parametros del producto

    Medición del VET

    Rango de medición0dB-60 dB
    Resolución0,1dB
    Precisión±1dB
    Pulso máximo por ciclo1400
    Banda de frecuencia de medición3~100MHz

    AE measurement

    Rango de medición0dB~60dB
    Resolución0,1dB
    Frequency Range±1dB
    Frequency Range20~200 kHz

    AA,AA1,AA2 measurement

    Rango de medición0dB~60dB
    Resolución0,1dB
    Precisión±1dB
    Frecuencia del centro del sensor40kHz

    UHF measurement

    Frecuencia de detección300-2000MHz
    Rango de medición0-60 dBV
    Sensibilidad<1dBm
    Banda de frecuencia del sensor300-2000MHz

    HFCT measurement

    Impedancia de transmisión del sensor5 mV/mA
    Frecuencia de detección1~30MHz
    Resolución0,1dB
    Sensibilidad≤50pC

    Hardware

    Caparazónabdominales
    Screen4.3 inch RGB LCD screen, resolution 800*480
    Sampling accuracy12bit
    Synchronization modeInternal synchronization
    ConectorInterfaz USB (también entrada de cargador)
    3.5mm stereo headphone jack
    Interfaz de entrada de sensor externo
    Earphone8 Ω minimum
    SD cardStandard configuration 16G ~ 64G
    Batería integrada3.7V/10000mAh lithium battery
    Operating hoursApproxi. 12 hours
    CargadorDC 5V/3A
    Temperatura de funcionamiento-20 ~ 50℃
    Humedad20-85% relative humidity
    Volume and weight210*100*35(mm) 0.4KG(host)
    Características del producto

    1、Configure different sensors to realize the partial discharge detection of almost all high-voltage electrical equipment;

    2、Provide a variety of discharge patterns such as time-domain waveform, PRPD, PRPS, etc., to realize the analysis of different discharge types;

    3、Humanized man-machine interface facilitates data management of different devices;

    4、Built-in ultrasonic sensor and transient ground voltage (hereinafter referredtoas TEV) sensor, which can be connected to special sensors such as transformers, GIS, overhead lines, cables, etc.;

    5、The non-invasive detection method does not require power failure during the test process, and there is no need to configure an additional high-voltage source, whichismore convenient to use than the traditional pulsed partial discharge detector factory;

    6、The test bandwidth range is 30kHz ~ 2.0GHz, which is suitable for the detectionprinciple of various frequency bands


    FAQs:

    Q:What is the UHV-8003 Handheld Ultrasonic Partial Discharge Detector? 

    A:The UHV-8003 is a portable partial discharge detection instrument designed to detect and analyze partial discharge signals from high-voltage electrical equipment. It can be used for equipment such as transformers, GIS, motors, cables, insulators, and overhead lines.

    Q:What is partial discharge (PD)? 

    A:Partial discharge is a localized electrical discharge that occurs in part of an insulation system without completely bridging the insulation between conductors. Continuous or severe partial discharge may indicate insulation defects and can contribute to insulation deterioration.

    Q:Can the UHV-8003 perform non-invasive testing? A:Yes. The product uses a non-invasive detection method and is designed to detect partial discharge without requiring an additional high-voltage test source. According to the manufacturer's product information, certain detection applications can be performed without shutting down the equipment.

    Q:How is the UHV-8003 different from a traditional offline partial discharge test system? A:A traditional offline PD test system generally requires a dedicated high-voltage test source and is often used for controlled laboratory or commissioning tests. The UHV-8003 focuses on portable, non-invasive field detection. It can receive PD-related signals without requiring an additional high-voltage source, making it particularly useful for inspection and condition assessment applications.








    También podría gustarte

    • ¡Tiene alguna pregunta!

      NO DUDE EN CONTACTARNOS EN CUALQUIER MOMENTO
      Contáctenos
    • Visítanos

      Edificio 6, Parque Industrial Óptico-Mecánico Optics Valley, 84 Gaoxin 5 Road,
      Zona de desarrollo de nuevas tecnologías de East Lake, ciudad de Wuhan, provincia de Hubei, China

    • Envíanos un correo electrónico

      qiao@hvtest.cc

    • Llámanos

      +86-15871365102