  • UHV(V) Lightning Impulse Voltage Generator System

    El sistema generador de voltaje de impulso de relámpago UHV (V) se compone principalmente de un generador de voltaje de impulso de relámpago, un gabinete de control de medición de impulso de relámpago, etc. Se utiliza para la prueba de voltaje soportado de onda completa, onda cortada y operación de impulso de relámpago para GIS, aisladores, transformadores, Bushing, aparamenta de alta tensión, disyuntor, interruptor de carga, gabinete de red en anillo.

     

    It has the features:

     

    1.Adopting PLC technology and using two core optical fibers to transmit control commands and feedback device status, thereby avoiding electromagnetic interference and improving the safety of the control system and computer.

    2.The control function has manual, fully automatic, and program control functions, and each level of function is relatively independent to ensure the reliability of the system.

    3.Adopting thyristor voltage regulation method and equipped with a charging voltage feedback measurement system.

    4.The ignition ball gap and cutoff ball gap distance can be manually and fully automatically adjusted, and displayed on the LCD panel.

    5.A cutoff trigger pulse with adjustable time delay and a feedback system with generator ignition trigger.

    6.By using a function controlled constant current charging method, the stability of the charging voltage can reach 0.5%.

    7.The LCD panel can indicate the charging voltage and charging process of the impact generator, with an accuracy of 1%.

    8.The charging voltage and time can be directly input from the LCD panel.

    9.Equipped with abnormal charging protection function, capable of fully automatic or manual triggering of ignition pulses

    10.Indication of the working status of the impact generator, such as spontaneous combustion, not triggered, abnormal charging, stable charging, etc.

    11.The grounding and grounding release control of the equipment body and charging part.

    12.The charging voltage polarity can be automatically switched through the buttons on the controller

    13.Charging process with automatic or manual control of charging voltage

    14.Can automatically or manually sound the alarm bell

    15.Equipped with automatic protection for overcurrent and overvoltageØ

    16.Isolation filter shielding design

    También podría gustarte

    • ¡Tiene alguna pregunta!

      NO DUDE EN CONTACTARNOS EN CUALQUIER MOMENTO
      Contáctenos
    • Visítanos

      Edificio 6, Parque Industrial Óptico-Mecánico Optics Valley, 84 Gaoxin 5 Road,
      Zona de desarrollo de nuevas tecnologías de East Lake, ciudad de Wuhan, provincia de Hubei, China

    • Envíanos un correo electrónico

      qiao@hvtest.cc

    • Llámanos

      +86-15871365102