  • Medidor probador de resistividad del suelo UHV-2571B

    Probador de resistividad del suelo con resistencia a tierra UHV-2571B, también conocido como probador de tierra de cuatro cables, probador de resistencia a tierra de precisión, etc. Es un tipo de instrumento que puede probar la resistencia a tierra y la resistividad del suelo.

    Detalles del producto del medidor probador de resistividad del suelo UHV-2571B


    Product introduction

    Wuhan UHV Power Technology Co.,Ltd., is a professional manufacturer and supplier of high-voltage power testing equipment in China.Didital ground resistance tester rejects the traditional manual manual power generation method, adopts advanced medium and large scale integrated circuit, and applies DC/AC conversion technology to combine the three-end button and four-end button measurement mode into a new type of Ground Resistance meter..

    The working principle is that the DC/AC converter in the machine changes DC into low-frequency constant current of AC, and the circuit is formed by auxiliary ground electrode C and measured object E, which generates AC voltage drop on the measured object, and is fed into AC amplifier for amplification through auxiliary ground electrode P, and then sent to the meter head for display through detection. With the aid of multiplying power switch, three different quantity limit can be obtained: 0 ~ 2 Ω, 0 ~ 20 Ω, 0 ~ 200 Ω.

    Didital ground resistance tester is suitable for measuring Ground Resistance of various devices and conductor Resistance of low Resistance in electric power, post and telecommunications, railway, communication, mining and other sectors; Didital ground resistance tester also measures soil resistivity and Ground voltage.


    PAGroduct functions

    Ground resistance testing: Accurately measures the ground resistance of grounding electrodes and grounding systems to determine whether grounding performance meets requirements.

    Soil resistivity testing: Uses the four-wire method to measure soil resistivity, providing data basis for grounding grid design and grounding engineering construction.

    Low resistance testing: Measures the resistance of grounding conductors, metal conductors, and connection points to check whether connections are reliable.

    AC grounding voltage testing: Detects the AC voltage of the on-site grounding system, assisting in evaluating the grounding environment and interference conditions.

    Anti-interference testing: Features power frequency and radio frequency interference suppression capability, suitable for complex on-site environments such as substations, distribution rooms, and grounding grids.

    Four-wire precision measurement: Reduces the influence of test leads and contact resistance on measurement results, improving the accuracy of ground resistance and soil resistivity testing.


    17


    Parámetros técnicos

     

    Las condiciones de trabajoTemperatura ambiente0℃~+45℃
    Humedad relativa≤85% HR

    Measurement range and constant

    current value (effective value)

    Resistencia0~20Ω(10mA),2~200Ω(1mA),20~2000Ω(0.1mA)
    VoltajeCA0~19,99V
    Precisión y resolución de la mediciónPrecision rowspan0~0,2Ω≤±3%±1d
    0.2Ω~1999.9Ω≤±1.5%±1d
    1~19,99V≤±3%±1d
    Resolución0.01Ω、0.1Ω、1Ω、0.01V

    Error de medición causado por auxiliar.

    Resistencia de puesta a tierra y tensión de tierra.

    Permitir resistencia de puesta a tierra auxiliarRC(between C1 and C2)
    0~20Ω≤1kΩ
    20~2000Ω≤2kΩ
    RP(between P1 and P2) < 40kΩ, Error≤±5%

    Voltaje de tierra permitido (efectivo

    valor de la frecuencia industrial)

    ≤5V, Error≤±5%
    Energía y consumo de energía.Pérdida de potencia máxima≤2W
    corriente continua8 × 1.5V (AA, R6) battery
    C.A.220V/50Hz
    volume and weightDimensiones220×200×105mm3
    Peso≤1,4 kg

    norteapodo: Probador de resistividad del suelo; medidor de resistividad del suelo


    Application Scenarios

    Substations: Testing the performance of substation grounding grids and grounding systems.

    Transmission and distribution lines: Testing the grounding resistance of transmission towers and distribution equipment.

    Power equipment grounding: Testing the grounding condition of transformers, switchgear, and other equipment.

    Building grounding systems: Testing lightning protection grounding, protective grounding, and other building grounding systems.

    Communication base stations: Testing the grounding resistance and grounding system performance of communication base stations.

    Grounding grid construction and acceptance: Measuring soil resistivity to provide a basis for grounding grid design, construction, and acceptance.

    Lightning protection grounding testing: Testing lightning rods, surge arresters, and lightning protection grounding devices.

    Industrial sites: Testing the grounding condition of factory equipment, distribution systems, and large machinery.

    Grounding system maintenance: Used for periodic inspections to identify abnormal ground resistance or grounding connection issues.


    Frequently Asked Questions

    Q: Why is it necessary to measure soil resistivity before grounding grid design?

    A: Soil resistivity is important basic data for grounding grid design, helping to determine the arrangement of grounding electrodes and the grounding scheme.

    Q: Can it be used for newly built grounding systems?

    A: Yes. It can be used for soil resistivity testing before construction, during construction inspection, and for ground resistance acceptance testing after completion.

    Q: What is the biggest feature of this device?

    A: It combines ground resistance and soil resistivity testing in a single device, while also supporting low resistance and AC grounding voltage testing.




    Características

    1 Cuerpo de carcasa de aleación de aluminio de alta resistencia, circuito equipado con bucle de bloqueo de fase y filtro de condensador conmutado, según el cual el instrumento desempeña un papel eficaz en el blindaje de la frecuencia eléctrica y la interferencia de radiofrecuencia.

    2 El convertidor CC/CA puede transformar la corriente CC en corriente constante de CA de baja frecuencia para la medición.

    3  Auxiliary grounding resistance can change in the range of 0 ~ 2KΩ (RC), 0 ~ 40KΩ (RP), that will not affect measurement results.

    4 Sin ajuste manual a cero, con pantalla LED de tres bits y medio, el instrumento se puede utilizar para medir la resistencia de puesta a tierra, la resistencia del conductor de baja resistencia, la resistividad del suelo y el voltaje de tierra de CA. Si el bucle probado falla, la pantalla muestra "1", lo que indica un rango grande, lo cual es consistente con las prácticas de medición convencionales.

    15. Aviso inteligente de subtensión de la batería para garantizar la precisión de la prueba.

    16. Tamaño pequeño y peso ligero.












    También podría gustarte

    • ¡Tiene alguna pregunta!

      NO DUDE EN CONTACTARNOS EN CUALQUIER MOMENTO
      Contáctenos
    • Visítanos

      Edificio 6, Parque Industrial Óptico-Mecánico Optics Valley, 84 Gaoxin 5 Road,
      Zona de desarrollo de nuevas tecnologías de East Lake, ciudad de Wuhan, provincia de Hubei, China

    • Envíanos un correo electrónico

      qiao@hvtest.cc

    • Llámanos

      +86-15871365102